126 Product Errata
41322 Rev. 3.84 August 2011
Revision Guide for AMD Family 10h Processors
416 DRAM Error Injection May Interfere With Power Management
Events
Description
The value in the NB Array Address Register (F3xB8) may change during a stop-clock throttling
event, C1E entry or C3 entry.
In addition, a non-zero value in F3xB8 may cause a failure during stop-clock throttling or C1E or C3
mode entry.
Potential Effect on System
Unpredictable system behavior.
Suggested Workaround
Diagnostic software should ensure that all power management events are disabled during a DRAM
error injection and should restore F3xB8 to zero before resuming these power management functions.
Fix Planned
No