392 XgOS User’s Guide • September 2014
b. For vHBAs, type:
When the State field shows active, the vHBA is up and connected.
19. Verify that the new software has been installed, type:
20. Enable the server profiles which you disabled in Step 5:
Proceed to “Upgrade Second ESX Server and Fabric Interconnect” on page 20-392 to
upgrade ESX Server 2 and Fabric Interconnect 2.
▼ Upgrade Second ESX Server and Fabric
Interconnect
1. Log in to ESX Server 2.
2. Use VMotion to move all guest machines off of ESX Server 2.
esxcfg-mpath -l
fc.5001397100002505:5001397000002505-
fc.2001000b08002539:2400000b08043110-eui.00
0b080074002539
Runtime Name: p3:C0:T0:L2
Device: eui.000b080074002539
Device Display Name:Pillar Fibre Channel Disk
(eui.000b080074002539)
Adapter: p3 Channel: 0 Target: 0 LUN: 2
Adapter Identifier: fc.5001397100002505:5001397000002505
Target Identifier: fc.2001000b08002539:2400000b08043110
Plugin: NMP
State: active
:
:
show system version
Build 3.6.0-XGOS - (root) Thu Jul 21 23:39:53 UTC 2011
set server-profile esx1 up
set server-profile esx2 up